THE MANAGERS
Why you need IMANAGER
Installing two service batteries in complete safety, avoiding the obsolete and inadvisable parallel, requires an electronic device that manages the system. With iManager you can install different batteries for: technology (Free acid, Gel, AGM), power and different age of the battery.
Choose your batteries with total freedom, iManager will take care of the rest!
Main Features:
- Automatic or manual management of one or two service batteries, even of different technology and amperage.
- Output dedicated to charging the engine battery, when the service batteries are 100% charged (e.g. storage).
- View the charge status of the batteries
- Displays charge and discharge voltage and Ampere
- Date and time display
- Automatic battery disconnection (under 11V) or manual, via touch display
- View information and advice on battery management and maintenance
- Temperature control during charging/discharging, for greater safety
- Black Box / Display connection available both via cable (code iM 12-150) and wireless (code iM 12-150W).
BLACKBOX:
Product Code IM 12-150
Connected battery consumption 8mA
Disconnected battery consumption 4mA
Automatic and Manual operation modes
Max current from relays 100A + 100A
Working voltage 12V (9V – 18V)
Working temperature -15°C / +65°C
Battery disconnection threshold Voltage: 10.5V – Temperature: 70°C
TOUCH DISPLAY:
Product Code IM 12-150
Max brightness consumption 86mA
Display consumption off 38mA
Disconnected battery consumption 8mA
Connection to Blackbox 7mm cable with low profile connector
Normal and Low Power Operation Mode
Display type TFT2.83” / 262k colors / touchscreen
Working temperature -10°C / +70°C
Reviews
There are no reviews yet.